This page covers the two kinds of calibration for Wuji Glove plus device parameter configuration. Hand model calibration drives the accuracy of joint angles and fingertip poses, and tactile calibration trains a contact model for contact detection. Calibration output is isolated per SDK user.
Hand Model Calibration
Hand model calibration is isolated per user, and the Default user can’t run it. Create a named profile, switch to it, then calibrate:Tactile Calibration
For contact detection, run tactile calibration. It records guided hand motions, trains a contact model for that glove, and provides live contact detection on thetactile_binary stream.
For the motion guide and command-line usage, see Wuji CLI tactile calibration. For the interface and data structures, see Tactile in SDK Reference.
Device Operations
User and Calibration Data
Calibration output and local data are isolated per SDK user, so switching users switches the active hand model. For user management and data export, see SDK User Management.Checks After Calibration
Confirm three things once calibration finishes:wuji doctorpasses, with no EMF disconnection and no tactile dead points, rows, or columns.wuji sub emf_poses --count 1returns a frame with normal confidence.- Flexing and extending the fingers produces continuous joint angles in the correct direction.