Skip to main content
This guide provides recommendations on control modes, parameter selection, and safe operation for WUJI Hand 2 in scenarios such as holding, teleoperation, debugging, fine manipulation, and policy deployment. This guide is updated as guidance evolves.

Check Versions and Operating Conditions

This guide applies to firmware v3.1.0 and later and SDK v2026.11.23 and later. Use wuji ping to check the device version and wuji upgrade to upgrade the firmware. See Upgrade Firmware.
  • Continuous operating time depends on ambient temperature, load, and the cooling configuration.
  • Keep the soft pads installed during operation.
  • For the supported supply voltage range and power supply specifications, see Power Supply.

Scenario Overview

Extended Holding and Transport

Use MIT-V2 to configure holding stiffness, damping, and output limits through kp, kd, and per-joint torque limits. Use the Base Configuration.

Teleoperation Data Collection: Everyday Objects

Prefer MIT-V2 for contact grasping. Configure the contact response through gains and torque limits. For glove tracking without contact, use position control mode to track target positions. Available configurations: Base, Softer, Stiffer, and Per-Finger Configuration for Everyday Objects. For position control settings, see Position Control Mode Parameters. After every 30–45 min of operation, open the hand, disable it, and rest for 5–10 min.

Initial Power-On and Debugging

Use MIT-V2 with the Initial Power-On and Debugging Configuration. This configuration keeps the base gains and uses lower per-joint torque limits. Monitor temperature during continuous unloaded operation. If a finger becomes blocked, open it within 1 min. Interpolate large movements on the host computer before sending commands.

Fine Manipulation and In-Hand Manipulation

Use MIT-V2 to configure the response through gains and per-joint torque limits. Available configurations: Base, Softer, Stiffer, and Per-Finger Configuration for Fine Manipulation. After 20–30 min of continuous operation, open the hand, disable it, and rest for 5–10 min.

Teleoperation Data Collection: Tools and High-Force Grasping

Use MIT-V2 with the short-duration configuration, which sets output limits by finger. Use the Short-Duration Configuration for Tools and High-Force Grasping. Keep each full-force closure to no more than 60–90 s. After 5–10 min of cumulative operation, rest for 10–15 min. These settings are for short-duration operation and should not be treated as continuous holding parameters.

Use MIT-V2

See Run an MIT Cosine Sweep. MIT-V2 stores kp and kd only for the current session. Both gains are 0 after each power-on. Set both gains again after each power-on and read them back to confirm the settings.

Use Position Control Mode

See Run a Position Mode Cosine Sweep.

Monitor the Hottest Joint and Handle Warnings

In every scenario, continuously monitor joint temperatures during operation and follow this section to respond to temperature readings and error codes. Use the operating and rest times in the scenario table to plan sessions. If a temperature warning occurs, take an earlier rest as described in the table below.

Find the Hottest Joint and Its Error Code

The reported operating temperature is the MCU temperature on the joint driver board, not the motor temperature. Subscribe to joint diagnostics through hand.joint_diagnostics() and read mcu_temp_c_fb. For the interface and subscription examples, see WUJI Hand 2 API: joint_diagnostics. To view the diagnostic stream through the CLI, run:
Check diagnostic data in this order:
  1. Compare mcu_temp_c_fb across joints in the same frame. The joint with the highest temperature is the current hottest joint. Keep updating this comparison because the hottest joint can change during operation.
  2. Read that joint’s nid and convert it to a joint index with WujiHand2.nid_to_joint_index(nid). Use the Joint Table, Indices, Units, and Control Frequency to identify the joint. The nid is not the joint index from 0 to 19.
  3. Read error_code_current for the same joint and follow the table below. Also check error codes on other joints. The hottest joint might not be the only joint with an issue.
Diagnostic frames include only online joints. If a joint is missing, no diagnostic frame arrives, or temperature data is abnormal, the available temperatures are not enough to determine the state of the whole hand. First follow Troubleshoot Faults and Resume Operation.

Respond to Temperature Readings and Error Codes

If the status light indicates an abnormal condition, read the error code through hand.joint_diagnostics() to identify the cause and follow this table. For other conditions, see Troubleshoot Faults and Resume Operation.

Provide Operating Information to Technical Support

When contacting technical support, include:
  • Device logs. See Export Device Flash Logs.
  • Hardware, firmware, and SDK versions.
  • kp, kd, and the effort_limit for each joint.
  • The grasped object and hand posture.
  • Continuous operating time.

Disable Before Disconnecting

Before exiting the host program or disconnecting, put down the object and disable the whole hand. If an emergency stop is needed, use the immediate stop operation.

Understand Why the Device Limits Output

Configured Torque Limits Cap Joint Output

effort_limit sets the maximum torque each joint can produce. It doesn’t mean the joint always produces that torque. MIT-V2 and position control mode share the runtime torque limits. When switching modes, set effort_limit again for the target mode. Position control mode includes integral control. When a finger is blocked, the joint continues driving toward the output limit and may keep reporting 0x0007. During contact grasping, continue monitoring temperature and adjust the torque limits accordingly.

Thermal Protection Further Limits Current

As temperature rises, the device reduces the maximum allowed current, which affects the available joint output: The temperature limit applies to the final combined current. Thermal protection still limits output even when effort_limit is set higher. If a temperature warning occurs, rest as described in Respond to Temperature Readings and Error Codes and meet the recovery conditions before resuming operation.

Parameter Configurations

Parameters are ordered by joint index from 0 to 19. See Joint Table, Indices, Units, and Control Frequency for the order. The units are N·m/rad for kp, N·m·s/rad for kd, and N·m for effort_limit.

MIT-V2 Configuration Comparison

Configurations with the same name use the same parameters across scenarios. This table lists the applicable scenarios and the number of joints whose settings differ from the base configuration.

Base Configuration

Applicable scenarios: extended holding and transport, everyday-object teleoperation, fine manipulation, and in-hand manipulation.

Softer Configuration

Applicable scenarios: everyday-object teleoperation, fine manipulation, and in-hand manipulation.

Stiffer Configuration

Applicable scenarios: everyday-object teleoperation, fine manipulation, and in-hand manipulation.

Per-Finger Configuration for Everyday Objects

Applicable scenario: everyday-object teleoperation.

Initial Power-On and Debugging Configuration

Applicable scenario: initial power-on and debugging.

Per-Finger Configuration for Fine Manipulation

Applicable scenarios: fine manipulation and in-hand manipulation.

Short-Duration Configuration for Tools and High-Force Grasping

Applicable scenario: tool and high-force grasping teleoperation.

Position Control Mode Parameters

When debugging position control mode, set each joint’s effort_limit to 50%–80% of the corresponding power-on default below, and set the position command low-pass cutoff frequency to 40 Hz. The array below lists the power-on default torque limits for reference. Running the code unchanged writes these defaults. For initial testing, multiply each value by 0.5–0.8 before writing the limits to the device.