This page gives diagnostic steps by symptom. For device stop behavior, emergency stop, the fault-clearing flow, and maintenance requirements, see Maintenance. For SDK installation, connection, and subscription problems, see Wuji SDK troubleshooting.
Device Discovery Failure
- Confirm the device has power and the status light reached white breathing.
- Confirm the network cable runs between the device port and the computer port with no loose connector.
- Confirm the computer adapter sits on the same subnet with subnet mask
255.255.255.0. - Run
ping 192.168.1.110for the left hand orping 192.168.1.111for the right hand. - Run
wuji devicesagain.
Connection Fails or IPs Collide
Two devices of the same handedness on one subnet ship with the same IP, which collides. Connect one at a time, change the IP of one following ip (SET/GET), reboot it, then connect both.The Status Light Shows a Warning or Fault
Match the light against Back-of-Hand Status Light in Product Introduction, then subscribe tojoint_diagnostics to read the exact error code and work through Clear Faults and Reset Safely.
Joints Offline (Fewer Than 20 Online)
- Read the actual count with
hand.online_joints_count().get(). - Subscribe to
joint_diagnosticsand locate the missing joint by each entry’snid. - Check whether that joint is jammed or its cable is under tension.
- Power-cycle and check again. If a joint stays missing, export logs and contact technical support.
Enable Fails
- Confirm no error code is active, and clear faults first if one is.
- Confirm the finger workspace is clear with no external constraint.
- Call
hand.enable()again and wait for the status word to reach Enabled. - After repeated failures, power-cycle and retry.
A Parameter Write Is Rejected
effort_limit and mit_params reject NaN, Inf, and negative values, and effort_limit also rejects values above the device ceiling. A rejected write leaves the value in effect unchanged, so read the current value back and retry within the ceiling. See Parameter Safety Limits.